HV coolant pumps

HV coolant pumps are engineered to guarantee proper reactor operation, overcoming cooling circuit resistance while delivering the necessary flow rate and pressure. The structure ensures mechanical efficiency, coolant isolation, and long service life.

  • Large flow, high head, high mechanical efficiency
  • Low conductivity for enhanced safety in high-voltage systems
  • The working medium is insulated from the outer surface, long-life
  • Different solutions to meet different demands

Main technical characteristics

PRODUCT MODEL

WCP31

WCP53

WCP74

Operating temperature range

-40~90 °C

-40~90 °C

-40~90 °C

Operating voltage

400~750 V

400~750 V

400~850 V

Control voltage

18~32 V

18~32 V

18~32 V

Rated head @ flow

≥15 m at 260 l/min

≥20 m at 360 l/min

≥24 m at 600 l/min

Rated power

≤1.5 kW

≤2.5 kW

≤4.5 kW

IP Grade

IP67

IP67

IP67

Lifetime

30,000 h

30,000 h

30,000 h

Picture of Vhit's HV coolant pumps
WCP31
Picture of Vhit's HV coolant pumps
WCP53
Picture of Vhit's HV coolant pumps
WCP74

This website does not use tracking tools. To offer you the best navigation experience, we only use technical cookies, including third-party cookies.